Specifications
Level One: Protege GX Installer Study Guide | August 2013 403
15. In each of the top panels, set the Type to Status List and choose a different list for each
Make sure you set the Rows to 2 in the right most panel
16. In the bottom left panel, set the Type to Event Windows and choose the All Events Record.
17. Adjust the Columns so it spans all 4 columns
18. Save the page
Task 7: Configuring Inputs
1. Rename the inputs as required based on their function:
Input Description
Input Description
CP1:1 Showroom (PIR)
RD1:1 Showroom Door (Reed)
CP1:2 Warehouse NW (PIR)
RD1:2 Showroom Door (REX)
CP1:3 Warehouse NE (PIR)
RD1:3 Showroom Door (Bond)
CP1:4 Warehouse SW (PIR)
RD1:4 -
CP1:5 Warehouse SE (PIR)
RD1:5 Showroom to Warehouse Door (Reed)
CP1:6 Warehouse Roller (Reed)
RD1:6 Showroom to Warehouse Door (REX)
CP1:7 -
RD1:7 Showroom to Warehouse Door (Bond)
CP1:8 -
RD1:8 -
Remember to use our consistent naming convention. So CP1:1, should become Showroom (PIR) MEL
CP1:1
2. Wire the inputs so they are closed.
3. Select all inputs (CTRL + A) and set the Input End of Line (EOL) values on the Options tab to match how
you have wired your inputs
4. Use the Find tool to locate the REX inputs
5. Set the Alarm Input Speed and Restore Input Speed to 50 msec