Specifications
402 Module 138: Programming Walkthrough | Step by Step Tasks
Task 6: Creating a Technician Status Page
1. Navigate to Monitoring | Setup | Status Lists
2. Change the name of the default status list to All Doors and Areas.
3. Click Add to open the Select Devices window
4. Set the Device Type to Door and choose your Controller
5. Select all doors, then click OK
6. Repeat steps 3 to 5 to add all areas to the status list
7. Add a new status list by clicking the Add button on the main toolbar
8. Call this one All Inputs
9. Change the device type to Input, select the Controller, then choose all of the inputs
10. Repeat to create additional status lists for All Outputs and All Trouble Inputs
You should now have 4 status lists:
11. Open the Status Page Editor: Monitoring | Setup | Status Page Editor
12. Name the page Technician, then scroll down and select the layout as shown
13. Click OK. This creates an empty page with a preset layout. The layout can be changed later, so this is just a
starting point.
14. Set the Columns to 4