Task 5: Creating Areas
1. Navigate to Programming | Areas and click Add to create the Showroom area
2. Select the Configuration tab:
Set the Entry Time to 10 seconds.
Set the Exit Time to 10 seconds.
Set the Alarm 1 Time to 1 minute.
3. Select the Outputs tab:
Set the Bell Output to CP001: Bell 0
Set the Exit Delay Output to RD1 Beeper R1
Set the Exit Delay Pulse On Time to 1
Set the Exit Delay Pulse Off Time to 9
Set the Entry Delay Output to RD1 Beeper R1
Set the Disarmed Output to <not set>
Set the Armed Output to RD1 Red R1
Set the Armed Pulse On and Armed Pulse Off Times to 5
4. Repeat these steps to create the Warehouse area, but using RD1 Beeper R2 and RD1 Red R2
5. Create a System area, setting the Entry and Exit delay times to 0.