Specifications

Level One: Protege GX Installer Study Guide | August 2013 389
15. Create Users, Assign Access Levels, and Add Cards
Create the following users, adding PINs and assigning the relevant access levels based on their role:
User Role PIN Card
Manny Jah Manager 1111 Card 1
Stu Roman Storeman 2222 Card 2
Whare Hausmann Storeman 3333 Card 3
Sel Ettuyu Sales Rep 4444 Card 4
Ike Cansalla Sales Rep 5555 Card 5
Add each of the training cards to the corresponding user
16. Add Power Supply Module and Trouble Inputs
Add the Power Supply module.
Add the relevant trouble inputs:
Input Number Description
AExxx:01 Module Tamper
AExxx:02 Mains Failure
AExxx:03 Low Battery / Battery Failure
AExxx:04 Output Voltage Low
AExxx:05 Output Over Current Failure
AExxx:06 Core Temperature Over Temp Failure
AExxx:08 Module Offline
Add the new trouble inputs to the All Trouble Inputs status list.
Wire the tamper input closed.
17. Add Trouble Inputs to the System Area
Add the Trouble Inputs to the System area, setting the input type to silent
18. Create a Report IP Service
Add a Report IP Service. For the purpose of this exercise, use the following details:
Client Code: 1234
IP Address: 123.45.67.89
IP Port: 9467
Reporting Protocol: ArmorIP (TCP) Encrypted