7. Configure Inputs
Name the inputs and set them up as required:
Input Description
Input Description
CP1:1 Showroom (PIR)
RD1:1 Showroom Door (Reed)
CP1:2 Warehouse NW (PIR)
RD1:2 Showroom Door (REX)
CP1:3 Warehouse NE (PIR)
RD1:3 Showroom Door (Bond)
CP1:4 Warehouse SW (PIR)
RD1:4 -
CP1:5 Warehouse SE (PIR)
RD1:5 Showroom to Warehouse Door (Reed)
CP1:6 Warehouse Roller (Reed)
RD1:6 Showroom to Warehouse Door (REX)
CP1:7 -
RD1:7 Showroom to Warehouse Door (Bond)
CP1:8 -
RD1:8 -
Wire them so they are closed. Ensure the EOL values are set to match the wiring.
Set the response time of the REX inputs to 50ms.
Set the PIR and Reed inputs to use the Instant type.
Assign the inputs to the appropriate areas.
8. Create a Door Type for the Showroom
Create a new Showroom door type
Set the operating schedule to the Showroom Door schedule
Set the secondary mode to Card Only
Set the primary mode to Card and PIN
9. Configure the Doors
Name both doors for easy identification.
Set the Showroom door to use the new Showroom door type.
Set the unlock schedule to opening hours.
Set the area inside for both doors.
Set the Door Lock follows... and Area disarmed AND… options for the Showroom door.
10. Setup Auto Disarming
Configure the Reader Expander so that both doors automatically disarm their area on valid access.