Specifications

350 Module 136: System Monitoring | Contact ID Monitoring
Set Phone Number 1 to the primary phone number of the monitoring station
Set Phone Backup to the second number we defined earlier. This number will be dialed if a connection
to the monitoring station cannot be made on the Phone 1 number. This can be an alternative monitoring
station.
Phone Number 2 is only programmed when you require monitoring signals to be sent to two different
phone numbers simultaneously. This is not a backup phone number.
6. Select the Options tab and enable the reporting options for the signals that you wish to be sent by this
service:
Open and Close: Reports all area arming and disarming signals. This is usually only enabled for
commercial premises.
Alarms, Tampers and Restore: Reports the corresponding input state changes.
Bypass: Reports if a user bypasses an input. This is usually only enabled for commercial premises.
7. Select the Settings tab