Specifications
Level One: Protege GX Installer Study Guide | August 2013 339
Areas
Trouble Inputs, just like physical inputs, must be programmed to an Area and assigned an Input Type before
they will generate an alarm.
Trouble Inputs can be assigned up to four areas, and will be processed individually by each area based on the
Input Type assigned.
Create a Trouble Area
To monitor Trouble Inputs, we will need a new area:
Navigate to Programming | Areas
Create a new area called System TXS
Switch to the Configuration tab and set the Entry and Exit delay times to 0
We want to be able to arm instantly
Trouble Input Pruning
Navigate to Programming | Trouble Inputs.
The Add Controller Wizard automatically added all possible trouble inputs for all the modules it created. To keep
the system tidy we will now go through and delete the irrelevant Trouble Inputs.
It is much quicker to use the Wizard to create everything, then delete the items that are not required.