Specifications

318 Module 135: Configuring Intruder and Access Integration | Configuring Office Access
Configuring Office Access
From the Protege GX user interface:
Set the Controller time to 7am on a weekday
Arm the Office area (if it isn't already armed)
Lock the Office Entry door (if it isn't already locked)
Now we're going to simulate the manager arriving in the morning:
Badge Card 2 at the Office Entry reader and enter the PIN 9998
Open the Office Entry Dr (Door) TXS CP1:1 input to simulate opening the door
Note the keypad starts entry delay
Door Areas
It makes sense that if a staff member is allowed access, the area should be turned off automatically for them.
We'll do this now...
The first step to configure this is to assign the area to the door:
Navigate to Programming | Doors
Select the Office Entry door and go to the General tab
Set the Area Inside Door to the Office area
Disarm On Entry
Navigate to Expanders | Reader Expanders and select RD1
Go to the Reader 1 tab and select (enable) the Disarm Area For Door On Access option
Save the changes