Specifications

Level One: Protege GX Installer Study Guide | August 2013 311
Reader Configuration
Select the Reader One tab. The Configuration options here define the behavior of the reader port 1.
By default, readers are configured for:
26 bit reading mode
As entry readers for access control
ARK-501 keypad (supports the ICT Multi Prox PIN input)
The Add Controller Wizard has automatically assigned each reader port to a door: RD1 to doors 1 and 2, RD2
to doors 3 and 4, and so on.
Reader Options
The Reader Options are where we configure which of the Reader Expander inputs will be associated with door
processing. We have used door sense (reed switches) for all of our doors, so will leave the Door sense enabled
option selected.
1. Select (enable) the Bond Sense Input Enabled for both Reader
One and Reader Two on RD1, and for Reader Two on RD2
This will enable bond sense on all doors except the Warehouse
Roller
2. Clear (disable) the REX Enabled option for Reader One and
Reader Two on RD2
Both the Warehouse Roller and Office to Warehouse door have
entry and exit readers and will not be using a REX input.