Specifications
308 Module 134: Basic Access Control | Door Configuration
Relock on Door Close
1. Badge Card 2 at the Managers Door reader
2. Open the Managers Dr (Door) TXS CP1:5 input
3. Close the Managers Dr (Door) TXS CP1:5 input
Notice that the lock output remains on for 5 seconds regardless of how long the door opens for
4. Select the Managers Office door and go to the Options tab
5. Enable the Relock on Door Close option and save your changes
6. Wait a few seconds then try simulating entering the Managers Office again
Notice that the door now locks as soon as it closes.
Door Options
There are many more door options that can be configured however these are outside of the scope of this
certification.
Reader Expander Configuration
While some functionality is configured at the door, many options around door processing is carried out at the
Reader Expander.
1. Navigate to Expanders | Reader Expanders
You'll see that the Add Controller Wizard has automatically created both Reader Expanders
2. Name the Reader Expanders using our naming conventions:
RD1 = Office Entry | Managers Office RD1 TXS
RD2 = Warehouse Roller | Office to Warehouse RD2 TXS
This way, we can use the find tool to find a particular door, module, or site.