Door Outputs
We configure the outputs under the Door's Outputs tab:
The Lock Output and Lock Output Group determine which output or output group to activate when the
door unlocks
The Lock Activation Time defines how long the door unlocks for (in seconds)
Note that the Add Controller Wizard has configured this automatically.
The Outputs tab is also where we configure outputs or output groups for:
Door Pre-Alarm
Door Left Open Alarm
Door Forced Open
These can be set to pulse in the same way we configured our area outputs.
By default, the Pre-Alarm and Left Open Alarm are configured to pulse the local reader beeper at different rates.
The Door Forced Open is not configured by default.