Specifications
274 Module 133: Basic Intruder Detection | Programming Inputs
Programming Efficiently
Now that you have programmed a number of inputs, we will look at how naming conventions will help us to
program a system efficiently. This is particularly important on a large system.
Program the Office Area Inputs
1. Click the Find button and type office into the Label field.
2. Click Ok. You should get a list of six inputs.
3. Click on one of the inputs then press CTRL + A to select all
4. Now hold down the CTRL key and click on Office Entry Dr (REX) to deselect it.
You should end up with five inputs selected as shown.
Note that the Door and Bond inputs are being used to trigger an intruder alarm. Inputs on Reader
Expanders can be used for alarm inputs as well as for access control. Both functions are processed
separately.
5. Click the Areas and Input Types tab:
Set the Area to Office TXS
Set the Input Type to Delay
Click Save
You have now programmed all of the required Office area inputs.
Program the Managers Area Inputs
1. Now use the find tool again with the word manager. Select all but the REX input:
2. Set the Area to Managers Office and the Input Type to Instant
3. Click Save