Specifications
Level One: Protege GX Installer Study Guide | August 2013 263
3. Select the Configuration tab:
Set the Entry Time to 10 seconds. This will allow any users that enter the area 10 seconds to disarm it
before the area generates an alarm
Set the Exit Time to 10 seconds. This will allow our users 10 seconds to exit the area once the arming
of the area has begun before an alarm is triggered
Set the Alarm 1 Time to 1 minute. This determines how long the bell/siren output for the area will
remain activated before timing out.
Normally we would use longer Entry and Exit times, but we will keep these short for our training system.
4. Select the Outputs tab:
Set the Bell Output to CP001: Bell 0
This determines the output that will be triggered when the area alarm is activated. In most cases, this
will be used to connect a siren.
The Exit Delay and Entry Delay Outputs are activated whenever the area starts the exit or entry delay cycle.
Using an audible output like the keypad beeper provides a distinctive warning to users to let them know the
area has begun arming and they need to get out, or that the entry delay period has been triggered and they
need to disarm the area before it generates an alarm.
Set the Exit Delay Output to KP1 Beeper
Set the Exit Delay Pulse On Time to 1
Set the Exit Delay Pulse Off Time to 9
Set the Entry Delay Output to KP1 Beeper
The Disarmed and Armed Outputs are activated whenever the area completes the disarming or the arming
cycle. Using an output such as a keypad LED provides a visual indication of the status of an area.
Set the Disarmed Output to KP1 Green LED
The Disarmed Indicator on the keypad will be green when the area is disarmed
Set the Armed Output to KP1 Red LED
The Armed Indicator on the keypad will be red when the area is armed
5. Click Save to finish configuring the Area