Specifications
Level One: Protege GX Installer Study Guide | August 2013 125
Relay Indicators
The Relay 1 and Relay 2 indicators show the status of the lock output relay.
State Description
On (red) Relay output is ON
Off Relay output is OFF
Zone (Input) Indicators
Whenever an input on the Controller is programmed with an input type and area, the input status is displayed on
the front panel (indicators 1-8) corresponding to the physical input number (Z1-Z8). This allows easy walk test
verification of inputs without the need to view the inputs from the keypad or Protege interface.
State Description
1
Off Input is not programmed
1
On (red) Input is in an OPEN state
1
On (green) Input is in a CLOSED state
1 1 1
Flashing (red) Input is in a TAMPER state
1 1 1
Flashing (green) Input is in a SHORT state
Reader Data Indicators
The R1 and R2 indicators display the status of the data being received by the onboard readers.
State Description
Short (red) flash
A SHORT flash (<250 Milliseconds) will show that data was received
but was not in the correct format.
Long (red) flash
A LONG flash (>1 Second) indicates that the unit has read the data
and the format was correct.
PSU Indicators
V1 Output/V2 Output Indicators
The V1 Output and V2 Output indicators will show the status of the 12VDC output.
State Description
Constantly on (green) 12VDC output operating OK
Continuous flash 12VDC output failure