Specifications

Level One: Protege GX Installer Study Guide | August 2013 113
Card Reader Connection
Both the Protege DIN Rail Controller and RDM2 provide access control functionality allowing the connection of 2
Wiegand devices to control 2 doors (entry or exit only) or they can be configured in multiplex mode to allow 4
Wiegand devices controlling 2 doors giving the flexibility of entry and exit readers without the need for additional
hardware.
The card reader must be connected to the Controller port using a shielded cable
Always refer to the card reader manufacturer for detailed installation guidelines
The shield connection must only be connected at one end of the cable in the metallic enclosure (frame
grounded)
Do not connect the shield to a V- connection on the Controller
Do not join the shield and black wires at the reading device
Do not connect the shield to any shield used for isolated communication
All Protege Readers are now shipped with single LED mode set as default.
The following diagram shows the connection of a standard Wiegand reader with the controller or RDM2
controlling an access door in entry or exit mode (2 doors, 2 readers).
Shield is frame
grounded at
one point
Shielded Cable
RED
BLACK
GREEN
WHITE
ORANGE
BROWN
BLUE
YELLOW
SHIELD
N/R
N/R
Shield not
connected
V+
V-Z4 V- Z3 Z2 V- Z1BZ L1 D1 DO