Specifications
104 Module 126: Limitations of SE Hardware in Protege GX | System Controller Compatibility
Controller Comparison
Records
PCB Controller
running GX Firmware
Protege GX DIN Rail
Controller
Cards per user 2 8
Access Levels per user 4 32
Doors in Access Levels Not supported 16
Door Groups in Access Levels 1 per controller 8
Floors in Access Levels Not supported 16
Elevator Groups in Access Levels 1 per controller 8
Floor Groups in Access Levels 1 per controller 8
PGM Groups in Access Levels 1 per controller 1
Menu Groups in Access Levels 1 per controller 1
Arming Area Groups in Access Levels 1 per controller 8
Disarming Area Groups in Access Levels 1 per controller 8
Outputs in Access Levels 1 per controller 16
Output Groups in Access Levels 1 per controller 1
Doors in a Door Group 64 64
Areas in an Area Group 128 128
Keypads in an Area Group 16 16
Outputs in an Output Group 24 24
Holidays in a Holiday Group 16 16
Elevators in an Elevator Group 128 8
Floors in a Floor Group 128 128
Storage Allocation
To assist in saving memory on the PCB Controllers, the Controller memory profile has a number of record types
that have restricted or no storage space allocated for the names assigned to records.
For example, the Controller can store up to 5000 users but there is only storage space allocated for the names
of the first 2000 users. This means that users 2001 – 5000 will not see their name displayed when logging in at
an LCD keypad, but will instead get a welcome message such as "Good Morning User 2001".
This only affects the display of devices connected to the controller (such as keypads) and does not mean that
events or reports created at the server have no names.