Specifications
PRT-WX-DIN Using Protege WX Installation and Programming Manual | June 2013
99
Recycle REX Time: When enabled, will restart the door open time allowing the door to be held open and
the REX pressed at each point the pre-alarm starts silencing the pre-alarm and restarting the open timer.
This allows a door to be held while furniture is being moved or to provide extended access for mobility
users.
Use Programmed Card Expiry: Used for short term users (such as visitors or hotel guests) that will be
configured with a start (check in) and end (check out) time, these options are designed to work with Hotel
card readers and allow the reader port to alter the access control decision of a user based on the data sent
from the guest card.
Expander Addressing
The Expander Addressing option is used to view the hardware that is connected to the system network, and to
set the addresses (see page 108) of the modules that have auto-addressing capability. This page displays the
details of all modules currently connected or that have registered previously but may currently be offline.
Listed for each module is:
The module type
The serial number
Current firmware version
The current address of the module
Whether the module is registered with the Controller
Whether the module is currently online