Reader Options
Allow Reading Opened/Unlocked: When enabled, the reader expander will send card information to the
system controller when a door is unlocked or opened. This option is set by default and should be left set if
the door control areas or time and attendance events are required from the reader port. When disabled the
reader performs no action when a card is presented and the door is unlocked or open.
Door Sense Enabled: When enabled the reader will send door events when the door input is opened or
closed. This is enabled by default but should be disabled on at least one reader port if both reader ports are
controlling the same door (ENTRY and EXIT access control).
Bond Sense Input Enabled: Enables the magnetic bond sense functions. The magnetic bond sense is a
contact that indicates if the magnetic bond between the electromagnet and the clamp is complete. It is
used when a separate door contact and bond sense input are to be used however the generation of door
events should be processed using both inputs.
REX Enabled: When enabled, the reader expander will generate request to exit events from the REX input
on the reader expander. When disabled the keypad will not generate any REX events.
REN Enabled: When enabled, the reader expander will generate request to enter events from the REN
input on the reader expander. When disabled no action will be taken for the Request To Enter function.
Intelligent Reader Tamper Mode: When enabled, the reader expander will assume that the external device
has smart messaging that allows a communication path to be formed from the reading devices (Card
reader) to the reader expander. When disabled the intelligent reader mode is disabled.
Misc Options
Disarm Area For Door On Access: When enabled, the reader process will disarm the area designated by
the reader type (Entry or Exit) and the door configuration programmed (if it has an area on the inside or
outside assigned). When disabled the reader will not perform any disarm functions.
Allow Access When Area Armed: When enabled, the user will be granted access based on the access
control configuration only and the area status will not be checked against the user's ability to disarm the
area. When the option is disabled and the user who is attempting access to a door that has an area
assigned that is armed and the user cannot disarm the area the user will be denied entry to the door even
though they may have the correct door and schedule settings.
Log Reader Events: When enabled, the reader events will be logged to the event review log. When
disabled the reader will not log the events to the event review log.
Swap Lock LED Display: When enabled, the LED display associated with the lock status will follow lock
output two. Use this option when a reader expander is used in an Entry and Exit configuration and only one
lock output is controlling the door. When disabled the lock and LED display is processed normally.
Display Card Detail When Invalid: When enabled, the reader expander will display the actual card data
received from the reader when the card number is not known. This option is enabled by default and can be
used to identify facility and card number details before adding card data to a user. When disabled, the
reader will display the card number not found message.