Specifications

92 PRT-WX-DIN Using Protege WX Installation and Programming Manual | June 2013
Output Expanders
Output Expanders extend the number of outputs available within the system.
General
Name: The name of the output expander.
Configuration
Physical Address: The device address of the Analog Expander.
Reader Expanders
Reader Expanders extend the number of reading devices and locking inputs available within the system.
General
Name: The name of the reader expander.
Configuration
Offline Operation: Defines the mode of offline operation allowed, enabling the reader to operate
autonomously if communications with the controller fail.
Physical Address: The device address of the Reader Expander.
Options
Multiple Reader Input Port 1: When enabled, the reader will process the multiplexed reader inputs on Port
1 so that dual readers can be connected for entry and exit processing. The duplex reader that is connected
will always operate as the exit reader. When disabled the reader port 1 interface will operate as a single
reader input.
Multiple Reader Input Port 2: When enabled, the reader will process the multiplexed reader inputs on Port
2 so that dual readers can be connected for entry and exit processing. The duplex reader that is connected
will always operate as the exit reader. When disabled the reader port 2 interface will operate as a single
reader input.