Specifications
PRT-WX-DIN Using Protege WX Installation and Programming Manual | June 2013
69
Advanced Options
Enable Stay Arming: When enabled the area can be stay armed.
Enable Force Arming: When enabled the area can be force armed.
Enable Instant Arming: When enabled the area can be instant armed.
Do Not Arm if Trouble Condition: When enabled the area will be prevented from arming if a trouble
condition is present in the system.
Prevent Arming On Count Not Zero: When enabled the area will be prevented from arming if the count
value for the area is greater than 0.
Always Verify Area Schedule: When enabled the area will verify that the programmed schedule has not
changed or the area has not been disarmed when it should have been armed. This will occur every one
minute period.
Area can be Reset: When enabled, allows the area to armed while it is already armed. This means that an
area that goes into alarm can be reset to the armed state, turning sirens and such off, without having to be
disarmed first. Use this option for areas that should never be disarmed.
Arming Options
Always Force Arm Using Card Reader: When enabled the area will force arm the area when the arming
process is started by a card reader.
Disable Exit Output on Stay Arming: When enabled the area will not activate the Exit Output when the
area is stay armed.
Clear Alarm Memory after Arming: When enabled the area clear all alarm memory when the area is armed.
Enable Late Arm Report: When enabled the area will generate Early to Arm and Late to Arm reportable
events according to the normal operating schedule (see above).
Enable Early Disarm Report: When enabled the area will generate Early to Disarm and Late to Disarm
reportable events according to the normal operating schedule (see above).
Disable Rearm on Schedule: When enabled the area will rearm as per the associated schedule.
User Rearm in Stay Mode: When enabled, a user that has the Rearm Area in Stay Mode option enabled
disarms the Area, the area will automatically rearm in Stay mode. Prior to rearming, the area will remain
disarmed for the length of time specified by the Rearm Area time setting.
Squawk Options
Bell Squawk on Arming Start: When enabled the area will squawk the Bell Output when the arming
process starts.
Bell Squawk on Arming Complete: When enabled the area will squawk the Bell Output when the arming
process is complete and the exit delay has ended.
Bell Squawk Only When Unattended: When enabled the area will only squawk the Bell Output when the
area is armed by an unattended arming, e.g. Card Reader, Remote Service, Key Switch, Door, another Area
etc.
Bell Squawk on Disarm: When enabled the area will squawk the Bell Output when the area is disarmed.
Bell Squawk on Successful Report: When enabled the area will squawk the Bell Output when the a
successful Area Armed report has been sent and acknowledge by a reporting service.
Schedule
Normal Disarm Schedule: Period 1 of the schedule defines the time period when the area can be
disarmed. If the area is disarmed before the start of Period 1 an Early to Disarm event will be generated. If
the area is still armed when Period 1 ends the System will generate a Late to Disarm event. No event is
generated if the area is disarmed while Period 1 of the schedule is valid.
Normal Arm Schedule: Period 2 defines the time period when the area can be armed. If the area is armed
before the start of Period 2 an Early to Arm event will be generated. If the area is still disarmed when Period
2 ends the System will generate a Late to Arm event. No event is generated if the area is armed while
Period 2 of the schedule is valid.