Areas | Options 1
General Options
Input Restore on Bell Cut-Off: When enabled the inputs that are assigned to this area will restore when the
bell time completes. This does not prevent the input from generating multiple alarms for another area when
this setting is specific to the area assigned. The inputs in the area will still log an event regardless of the bell
time to prevent an input from triggering an event remove the event log option in the input configuration.
Setting this option will prevent the retrigger bell timer from operating in the input type. Do not use this option
for an area that is used for automation control or motion controlled lighting.
Re-Arm Enabled: When enabled the area will re-arm if the area is disarmed. This feature is used for dead
man timers and areas that should not remain disarmed for a longer than a predefined time. For this option
to operate the re-arm time must be set to a value greater than 0.
Arm Child Area: When enabled the child area will be armed when the parent (this) area is armed. Can be
used in conjunction with the option below.
Arm Child If All Other Areas Are Armed: When enabled the child area will only be armed if ALL the areas
that the child area are assigned are armed. Use this option when multiple areas are assigned the same child
area that needs to be controlled with a specific disarming and arming order. This effectively allows an OR
and AND operation to be done on the child area.
Disarm Child Area: When enabled the child area will only be disarmed when the parent (this) area disarms.
Disarm Child If All Other Areas Are Disarmed: When enabled the child area will only be disarmed if ALL
the areas that the child area are assigned are disarmed. Use this option when multiple areas are assigned
the same child area that needs to be controlled with a specific disarming and arming order. This effectively
allows an OR and AND operation to be done on the child area.
Use Unattended Brute Force Arming: When enabled the area will be prevented from arming if an input
that is not a force enabled input is open when the area is armed in an unattended mode.
Area Enabled In Loiter Mode: When enabled the area will control the users that access the area for a
period of time assigned to the loiter control time. If a user breaches the allocated time the user will be set to
the area programmed in the loiter area setting.