Specifications
66 PRT-WX-DIN Using Protege WX Installation and Programming Manual | June 2013
Armed Pulse On Time: The armed output pulse on time is used to make the output pulse on and off
when activated. The value entered here must be greater than 0 and is in increments of 100ms. For
example setting 10 will pulse the unit on for 1 second and then off for the programmed time set in the
pulse off section.
Armed Pulse Off Time: The armed output pulse off time is used to make the output pulse on and off
when activated. The value entered here must be greater than 0 and is in increments of 100ms. For
example setting 10 will pulse the unit off for 1 second and then on for the programmed time set in the
pulse on section.
Bypassed Inputs Output/Output Group: You can assign a output or output group to activate whenever
the area has a bypassed input. The bypass output or output group will be deactivated when the area
completes the disarming cycle.
Bypassed Inputs Pulse On Time: The bypass output pulse on time is used to make the output pulse
on and off when activated. The value entered here must be greater than 0 and is in increments of
100ms. For example setting 10 will pulse the unit on for 1 second and then off for the programmed time
set in the pulse off section.
Bypassed Inputs Pulse Off Time: The bypass output pulse off time is used to make the output pulse
on and off when activated. The value entered here must be greater than 0 and is in increments of
100ms. For example setting 10 will pulse the unit off for 1 second and then on for the programmed time
set in the pulse on section.
Tamper Alarm Output/Output Group: You can assign an output or output group to activate whenever the
area has a tamper alarm. The tamper output or output group will be deactivated when the area completes
the disarming cycle on the 24HR portion of the area.
Tamper Alarm Pulse On Time: The tamper output pulse on time is used to make the output pulse on
and off when activated. The value entered here must be greater than 0 and is in increments of 100ms.
For example setting 10 will pulse the unit on for 1 second and then off for the programmed time set in
the pulse off section.
Tamper Alarm Pulse Off Time: The tamper output pulse off time is used to make the output pulse on
and off when activated. The value entered here must be greater than 0 and is in increments of 100ms.
For example setting 10 will pulse the unit off for 1 second and then on for the programmed time set in
the pulse on section.
Alarm Memory Output/Output Group: You can assign an output or output group to activate whenever the
area has an alarm and the output or output group will remain activated. The memory output or output group
will be deactivated when the area completes the disarming cycle. Use this to drive local indicators on
keypads, card readers and relays for signaling that the system has had an alarm activation.
Alarm Memory Pulse On Time: The memory output pulse on time is used to make the output pulse on
and off when activated. The value entered here must be greater than 0 and is in increments of 100ms.
For example setting 10 will pulse the unit on for 1 second and then off for the programmed time set in
the pulse off section.
Alarm Memory Pulse Off Time: The memory output pulse off time is used to make the output pulse on
and off when activated. The value entered here must be greater than 0 and is in increments of 100ms.
For example setting 10 will pulse the unit off for 1 second and then on for the programmed time set in
the pulse on section.
Area Defer Arming Started Output: You can assign a output or output group to activate whenever the
area begins the defer warning cycle and is about to arm. The defer warning time is programmed in the defer
time setting. The defer output or output group will be deactivated when the area begins the arming cycle or
when the defer time is canceled by a user.
Defer Arming Started Pulse On Time: The defer output pulse on time is used to make the output
pulse on and off when activated. The value entered here must be greater than 0 and is in increments of
100ms. For example setting 10 will pulse the unit on for 1 second and then off for the programmed time
set in the pulse off section.
Defer Arming Started Pulse Off Time: The defer output pulse off time is used to make the output
pulse on and off when activated. The value entered here must be greater than 0 and is in increments of
100ms. For example setting 10 will pulse the unit off for 1 second and then on for the programmed time
set in the pulse on section.
Fail to Arm Output/Output Group: You can assign an output or output group to activate whenever the
area fails to arm.