Specifications

PRT-WX-DIN Using Protege WX Installation and Programming Manual | June 2013
65
Bell Output/Output Group: You can assign a bell/siren output or output group to activate whenever the
area goes in to alarm. The input that triggers the alarm must have the bell output option enabled for the
input type. The bell/siren output and output Group will be deactivated when the bell timer times out or when
the area is disarmed, the bell/siren may also be disarmed when the user logs in to the keypad.
Bell Pulse On Time: The bell/siren pulse on time is used to make the output pulse on and off when
activated. The value entered here must be greater than 0 and is in increments of 100ms. For example
setting 10 will pulse the unit on for 1 second and then off for the programmed time set in the pulse off
section.
Bell Pulse Off Time: The bell/siren pulse off time is used to make the output pulse on and off when
activated. The value entered here must be greater than 0 and is in increments of 100ms. For example
setting 10 will pulse the unit off for 1 second and then on for the programmed time set in the pulse on
section.
Exit Delay Output/Output Group: You can assign an exit delay output or output group to activate
whenever the area starts an exit delay cycle. The exit delay output or output group will be deactivated when
the area completes the arming cycle or if an alarm occurs during the exit delay period. Disarming the area
will also result in the exit delay output or output group being deactivated.
Exit Delay Pulse On Time: The exit delay output pulse on time is used to make the output pulse on
and off when activated. The value entered here must be greater than 0 and is in increments of 100ms.
For example setting 10 will pulse the unit on for 1 second and then off for the programmed time set in
the pulse off section.
Exit Delay Pulse Off Time: The exit delay output pulse off time is used to make the output pulse on and
off when activated. The value entered here must be greater than 0 and is in increments of 100ms. For
example setting 10 will pulse the unit off for 1 second and then on for the programmed time set in the
pulse on section.
Entry Delay Output/Output Group: You can assign a entry delay output or output group to activate
whenever the area starts an entry delay cycle. The entry delay output or output group will be deactivated
when the area is disarmed during the entry delay period or the area activates the alarm due to the entry
delay timing out.
Entry Delay Pulse On Time: The entry delay output pulse on time is used to make the output pulse on
and off when activated. The value entered here must be greater than 0 and is in increments of 100ms.
For example setting 10 will pulse the unit on for 1 second and then off for the programmed time set in
the pulse off section.
Entry Delay Pulse Off Time: The entry delay output pulse off time is used to make the output pulse on
and off when activated. The value entered here must be greater than 0 and is in increments of 100ms.
For example setting 10 will pulse the unit off for 1 second and then on for the programmed time set in
the pulse on section.
Disarmed Output/Output Group: You can assign a output or output group to activate whenever the area
completes the disarming cycle. The disarmed output or output group will be deactivated when the area
completes the arming cycle. Use this to drive local indicators on keypads, card readers and relays for
signalling that the system is disarmed and can be entered. This can also be used for interlocking non reader
controlled doors to prevent entry to areas if the area is armed. Use this output in conjunction with user
area's to control multiple storage lockers or storage facilities.
Disarmed Pulse On Time: The disarmed output pulse on time is used to make the output pulse on and
off when activated. The value entered here must be greater than 0 and is in increments of 100ms. For
example setting 10 will pulse the unit on for 1 second and then off for the programmed time set in the
pulse off section.
Disarmed Pulse Off Time: The disarmed output pulse off time is used to make the output pulse on and
off when activated. The value entered here must be greater than 0 and is in increments of 100ms. For
example setting 10 will pulse the unit off for 1 second and then on for the programmed time set in the
pulse on section.
Armed Output/Output Group: You can assign a output or output group to activate whenever the area
completes the arming cycle. The armed output or output group will be deactivated when the area
completes the disarming cycle. Use this to drive local indicators on keypads, card readers and relays for
signalling that the system is armed.