Activate Entry Output on Bell Time: When enabled the input type will activate the entry output
programmed for the area for the duration of the bell siren time. Use this feature for an input that you want to
only generate a beeper alarm and assign the entry output a keypad beeper output. This option will not
function if the bell option is enabled.
Output Activation Options
Activate Bypass Output: When enabled the input type will activate bypass output for the area if an input is
bypassed.
Activate 24hr Tamper Output: When enabled the input type will activate the tamper output for the area if a
tamper alarm occurs.
Activate Memory Output: When enabled the input type will activate the memory output for the area if an
alarm occurs. This option can be used to indicate that an alarm has occurred in the system. Use this feature
to display an indication to the users of the system to prevent possible "Sitter and Hostage" situations.
Input Retriggers Output Time: When enabled, reinitiates the activation time of an output when the input is
triggered, for example reactivating lights when a motion sensor is triggered.
Input Types | Options 3
Control Options
Use Input Type Output Time: When enabled the input will activate the output timed (if a time is
programmed) and use the Output Time Set in the Input Type. If the input type does not have a time
programmed no time will be used.
Toggle Input Output State: When enabled the input control output will be toggled when the input goes in
to alarm. You can use this option to activate a output on alarm and deactivate on the next alarm. This is
ideal for lighting control and automation applications.
Activate Input Control Output On Alarm: When enabled the input type will activate the input control
output when the input assigned generates an alarm.
Activate Input Control Output On Restore: When enabled the input type will activate the input control
output when the input assigned restores from an alarm.
Deactivate Input Control Output On Alarm: When enabled the input type will deactivate the input control
output when the input assigned generates an alarm.
Deactivate Input Control Output On Restore: When enabled the input type will deactivate when the input
control output assigned restores from an alarm.