Specifications

60 PRT-WX-DIN Using Protege WX Installation and Programming Manual | June 2013
Report Bypass: When enabled the input type will generate a reportable bypass message.
Report Restores: When enabled the input type will generate a reportable restore message.
Stay Input: When enabled the input type will generate an alarm if the area is armed in stay mode. The input
will stay armed. For inputs that will be active when an area is armed in stay mode it is recommended to
disable the event log for the input.
Force Input: When enabled the input type will allow the inputs it is assigned to be force armed.
Exit Alley Input Do Not Test It: When enabled the input type will not verify the status of an input prior to
the area starting to arm. Use this feature to assign inputs in exit locations to prevent the area from
generating an input open warning when being armed.
Recycle Input Alarm on Exit Delay End: When enabled the input type will recheck the inputs it is assigned
when the area completes the exit delay cycle and if an input is open recycle the input to force it in to
generating an alarm. Use this feature for an input type used on an input that may be breached during the
exit delay such as a window or door contact.
Input Types | Options 2
Miscellaneous Options
Activate Bell Output: When enabled the input type will activate the siren bell output programmed for the
area.
Retrigger Bell Time: When enabled the input type will restart the bell timer on each subsequent alarm
Save To Area Memory: When enabled the input type will save an alarm message to the area's alarm
memory storage area.
Disarm Control Area On Input Restore: When enabled the input type will disarm the control area when an
input assigned the input type restores from an alarm condition. Use this feature and the arming control area
feature as a on and off key switch arming input.
Arm Control Area On Input Alarm: When enabled the input type will start arming the control area when an
input assigned the input type generates an alarm condition.
Toggle Control Area On Input Alarm: When enabled the input type will toggle the state of the control area
when the input that is assigned this input type generates an alarm.
Allow Force Arming Of Tampered Input: When enabled the input type will allow the input to be force
armed if the input assigned the input type is tampered.