Specifications

58 PRT-WX-DIN Using Protege WX Installation and Programming Manual | June 2013
Door Types | Options
Door REX Not Allowed: When enabled the door will disable the REX (request to exit) operation.
Door REN Not Allowed: When enabled the door will disable the REN (request to enter) operation.
Input Types
Input types define how an input will operate in an area.
General
Name: The name of the input type.
Configuration
Operating Schedule: Determines when the input type is valid and if it will use a secondary input type when
the schedule is not valid.
Secondary Input Type: Allows an input to have a secondary configuration when that Operating Schedule is
invalid. This option is only enabled when the Operating Schedule is not set to Always.
Keypad Alarm Display Group: Determines which keypads will be presented with alarm information when
the input that the input type is assigned generates an alarm.
Custom Reporting Code: Each input type has a default reporting code already assigned which determines
the code that is sent to the central station when an alarm is generated. This option enables you to change
the reporting code of the inputs to which this input type is assigned.
Control Output Time: You can override the programmed activation time for an output by setting an
activation time in the input type.
Control Output / Output Group: You can assign an output or output group to activate whenever an input
type process's an alarm or restore for an input. The input type must have the control output options set in
the Output options.
Control Area: An input type can be programmed to control the arming and disarming state of an area from
an input (key switch control). The area to be controlled by the input type must be programmed with the
force arming option. Arming using an input type is deemed to be an unattended arming condition and
therefore the system will attempt to arm the area in the force mode.