Specifications

PRT-WX-DIN Using Protege WX Installation and Programming Manual | June 2013
39
Bell Indicator
The Bell indicator shows the status of the bell output and the over current or circuit fault conditions.
State Description
Off Bell is connected, output is OFF
On (green) Bell is ON
Single (green) flash Bell is ON, the circuit is in over current protection
Two (green) flashes
Bell is OFF, the circuit to the siren/bell is cut, damaged or
tampered
Relay Indicators
The Relay 1 and Relay 2 indicators show the status of the lock output relay.
State Description
On (red) Relay output is ON
Off Relay output is OFF
Zone (Input) Indicators
Whenever an input on the Controller is programmed with an input type and area, the input status is displayed on
the front panel (indicators 1-8) corresponding to the physical input number (Z1-Z8). This allows easy walk test
verification of inputs without the need to view the inputs from the keypad or Protege interface.
State Description
1
Off Input is not programmed
1
On (red) Input is in an OPEN state
1
On (green) Input is in a CLOSED state
1 1 1
Flashing (red) Input is in a TAMPER state
1 1 1
Flashing (green) Input is in a SHORT state