Specifications
PRT-WX-DIN Using Protege WX Installation and Programming Manual | June 2013
27
3. Click Save and Continue to proceed and configure Offsite Monitoring. All modules will be restarted
automatically.
4. If using PSTN Monitoring, enter the Dialler information:
Set the Primary Phone Number of the monitoring station
Set the Backup Phone Number of the monitoring station. This number will be dialed if a connection
with the station cannot be made on the primary phone number.
Enter the Client Code (or account number). This is the code used to identify the system at the
monitoring station and will usually be issued by the monitoring company.
5. If using IP Reporting:
Enter the IP Address and IP Port Number as supplied by your monitoring station.
If the monitoring station has a backup path, enter the secondary IP Address 2 and the Secondary IP
Port 2 Number to be used if the first IP address fails.
Select the Reporting Protocol to be used This will usually be supplied by your monitoring station.
If using an encrypted protocol, select the Encryption Level and the Encryption Key to be used
If required, adjust the Poll Time. One of the advantages of IP reporting is that essentially it is always
'on'. This is achieved by sending regular poll messages at the frequency set here. This defaults to 30
seconds, however your monitoring station may request a different setting.
Enter the Client Code (or account number). This is the code used to identify the system at the
monitoring station and will usually be issued by the monitoring company.
6. Click Save and Return to Menu to complete configuration and return to the setup menu