Specifications

PRT-WX-DIN Using Protege WX Installation and Programming Manual | June 2013
25
3. Click Save and Continue to proceed to step 2.
4. Select the Unlock Schedule if required then click Save and Return to Menu.
Progress is shown as the Doors are created. Once finished, you are returned to the Home page.
Security
The Security Wizard allows you to configure the Areas in your system, the Inputs that are used to trigger events,
and setup basic offsite monitoring services.
This step disarms any areas that are currently armed, and will prompt you to confirm the action.
1. The wizard lists the placeholder Area that is created by default which you can now edit to fit your needs. If
you require additional areas, you can create these first, or create and configure them later.
Select the Bell Output and the Bell Time. This is the output that will be triggered when the area alarm is
activated and the time it will be activated for. In most cases, this will be used to connect a siren.
Select the Entry Delay Output and the Entry Delay Time. This is the output that will be activated
whenever the area goes into entry delay and the time users will be given to disarm the area before an
alarm is triggered.
Select the Exit Delay Output and the Exit Delay Time. This is the output that will be activated
whenever the area goes into exit delay and the time users will be given to exit the area before an alarm
is triggered.