Specifications

102 PRT-WX-DIN Using Protege WX Installation and Programming Manual | June 2013
Options
Test Report Time is Periodic: When enabled, the test report trouble input will be activated at the
frequency defined by the Test Report Time. When disabled the test report trouble input will be activated at
the specified time of day.
Generate Input Restore On Test Report Input: When enabled the Controller will generate a restore event
for the trouble input test report input restoring. This occurs one minute after the trouble input has been
activated.
Misc Options
Enable Automatic Offline Download: When enabled the Controller will automatically update offline
configuration parameters to all intelligent (RDI2, RDE2) modules at the time programmed in the Automatic
Offline Time.
Log All Access Level Events: When enabled the Controller will generate events including the reason a user
was denied access if they do not have the required access rights.
Treat User PIN +1 as Duress: When enabled, treats the last digit of a user's pin plus 1 as a duress code.
For example, if the user pin is 1234 but the pin is entered as 1235, it will be processed as a duress code.
Note that the plus 1 counter applies to the last digit only. This means if the user pin is 1239, the pin to
trigger a duress code would be entered as 1230.
Operators
An operator is a person that uses Protege WX for maintaining the system and monitoring the site.
General
Name: The name of the operator. This is the name that is displayed in the status bar at the top of the page.
Configuration
Username: The username of the operator. This is the name used when logging in.
Password: The password of the operator.
Role: Select the appropriate role to determine what access the operator has once logged in.