Specifications

68 CHAPTER 6: MAINTENANCE
087-0048 REV B SCOTT SAFETY
Maintaining the Test
Station
Refer to Table 22 for maintenance of the Test Station.
Error Codes Table 23 provides a list of error codes for the Protege ZM.
Table 22 Test Station Maintenance
ITEMS
Inspect the Test Station before and after each use to ensure all components are in operating
order and undamaged.
Ensure the Gas Cylinder has adequate gas for testing purposes.
Inspect each Sensor Cavity to ensure that each opening is free and clear of debris.
Inspect the AC Power module and ensure it is undamaged.
Clean the Test Station, remove devices and disconnect from power source. Use only a soft
cloth to wipe surfaces. If necessary, a mild detergent may be used. Dry thoroughly before
applying power or replacing devices.
Table 23 Protege ZM Error Codes
ERROR
CODES CAUSE SOLUTION
E01 Configuration memory
corrupt
Press the button to acknowledge the error. Then
reconfigure the device using the IR Connect.
E02 Gas memory corrupt Press the button to acknowledge the error. Then
reconfigure the device using the IR Connect.
Calibrate the device.
E03 Program memory corrupt Press the button to acknowledge the error. Then
attempt to load a new firmware image into the device
via the IR Connect. If that is unsuccessful, then
contact us.
E05 Bad battery Contact us.
E06 Bad sensor Contact us.