Specifications

58 CHAPTER 6: MAINTENANCE
087-0048 REV B SCOTT SAFETY
Saving the Event Log This section describes saving the Monitors event log using the IR Connect Software.
By default the monitor stores the last twenty-five (25) alarm events. It stores events
using a First In First Out (FIFO) method. That is, the twenty-six event replaces the
first event and so on. This information may be downloaded to a PC using the IR
Connect Software. For each alarm event the monitor records the following:
Product Name
Log Type
Serial Number
Firmware Version
ID
Life Remaining
Total Number of Events
Duration of Events
Number of Self-Tests
Event Date
Event Time
Bump Test (Yes or No)
Duration (Seconds)
Sensor Reading (PPM or %)
Alarm Condition (Low, High or OL)
We recommend saving its event log prior to placing the monitor in hibernation. To
save the log, click on SAVE EVENT LOG. This allows the selection of a specific folder
to save the event log to. Once hibernation occurs, all prior event logs are erased.
1 Position the monitor in front of the IR Connect. Perform a READ DEVICE prior to
performing any upgrades to ensure communication has been established.
2 Click on SAVE EVENT LOG to save the log. This allows the selection of a
specific folder to save the event log. See Figure 39.