Specifications

46 CHAPTER 5: OPERATION
087-0048 REV B SCOTT SAFETY
Monitor LCD Alerts &
Alarms
This section describes various alerts and alarms.Table 17 lists the details.
Hibernating the
Monitor Using the IR
Connect
This section describes hibernating the monitor using the IR Connect and the IR
Connect Software. This only applies to specific devices designed for hibernating.
This assumes the IR Connect Software is already installed.
1 Ensure the IR Connect USB Cable is connected.
2 Click READ DEVICE on the IR Connect Software.
When the Device is hibernated, the event log is cleared. It is highly recommended to
save the event log by clicking SAVE EVENT LOG before hibernating.
3 Click HIBERNATE, acknowledge the event log message.
4 Ensure the monitor is kept in front of the IR Connect until the “Hibernate OK”
message is displayed at the bottom of the IR Connect Software.
5 Confirm the Monitors LCD is blank.
6 If you encounter any problems, please contact us.
Table 17 Monitor Alerts and Alarms Descriptions
LCD REASON LED BEEPS VIBRATION
Low Alarm 1 slow flash
every second
1 slow beep
every second
1 slow
vibration every
second
High Alarm
and Over
Limit (OL)
Alarm
2 fast flashes
every second
2 fast beeps
every second
2 fast
vibrations
every second
Detector Life
Countdown
Alarm*
8 slow flashes
per minute
8 slow beeps
per minute
8 slow
vibrations per
minute
Bump Test
Due**
Note: LCD
toggles
between BUP
& reading.
Emits
alternating
flashes (left
and right)
every 5
seconds
* When the Monitor remaining clock displays 0 hours the detector operates for 8 hours
before deactivating.
** This applies only when a bump test interval is set.