Specifications

Configuring the Test Station Software Parameters 37
SCOTT SAFETY 087-0048 REV B
After configuration changes, click WRITE. If a successful write, a Green Bar appears
in the bottom right hand corner of the screen.
Figure 29 shows the Protege ZM Tab and Table 14 details the parameters. These
parameters allow you to configure each sensor type to met your needs. Once this
configuration has been sent to the Test Station, every monitor that is Bump Tested
takes on these new configuration parameters.
Table 13 Test Station Software Parameters
ITEM DETAILS
Location User adjustable text field that is logged with each test. Used to
assign a unique name to the Test Station. This appears on the test log
file. For example, “Tailer 57 Test Station”.
Number Event Logs Specifies the number of consecutive monitor event logs to store and
to transfer from monitor to Test Station.
Default= 10
Range= 0 to 500
Auto Power-Off Time After performing a test, the Test Station powers off after 120
seconds. To change, select from the other options.
Default=120seconds
Range=0 to 3600seconds.
Maximum Bump
Time
Maximum time to apply gas if a sensor isn’t responding.
Default=30seconds
Range=20 to 80seconds.
Gas Bottle Fields Note: Verify the entries and make sure they match the gas bottles in
use. If gas bottles and the mixture change, update the gas
concentrations in these boxes or the tests will be inaccurate.
Allows entering information pertaining to the calibration gas.
Expiration Date and Bottle Lot# appear on each test record. If the
expiration date is set to today’s date, that field remains blank on the
test record.
Note: Changing any of the Testing Check Boxes may disable key
testing functions.
Note: Click on the arrow to access the pull-down calendar and select
a specific date.
Note: Update expiration date, bottle lot and mixture data each time a
new bottle of Calibration Gas is inserted into the Test Station.
Firmware Upgrade Allows Firmware upgrades during the life of the Test Station. These
may be product improvements to add additional features or to
enhance monitors performance. Most firmware upgrades are not
required unless notified by us. To see if your monitor has the most
current version, please contact us.
Allow Calibrations Can optionally enable/disable calibrations form the Test Station.
Allow Bump Tests Can optionally enable/disable bump test form the Test Station.
Allow Hibernate Can optionally enable/disable 2 button press to hibernate CO and
H
2
S monitors.
Allow Configurations Can optionally enable/disable re-configuring the monitors.
Allow Firmware
Upgrade
Can optionally allow Monitor firmware upgrades to the image stored
on the Test Station.