Specifications

80 APPENDIX A: SPECIFICATIONS
087-0048 REV B SCOTT SAFETY
Specifications Table 26 lists the monitors specifications. Table 27 lists the IR Connect
specifications. Table 28 lists the Test Station specifications.
Table 26 Monitor Specifications
MONITOR SPECIFICATIONS
Battery Life 2 years, 4 minutes of alarm time per day
Alarms Visual, vibrating, audible 95dB
Tests Full function self-test on activation and every 20hours;
continuous automatic battery tests
Data Log Last 25 events
Housing Impact Adsorbent Overmold
Hydrogen Sulfide Range 1 to 100PPM, 1PPM
Low Alarm Set Point 10PPM*
High Alarm Set Point 15PPM*
Calibration Gas
Concentration
25PPM
Carbon Monoxide Range 1 to 300PPM, 1PPM
Low Alarm Set Point 35PPM*
High Alarm Set Point 200PPM*
Calibration Gas
Concentration
100PPM
Oxygen Range 1 to 30% Volume, 0.1%
Low Alarm Set Point 19.5%*
High Alarm Set Point 23.5%*
Calibration Gas
Concentration
16%
Dimensions 3.7Hx2.2Wx1.3”D (94Hx56Wx33mmD)
Weight 2.7oz (76g)
Intrinsically Safe
Approved
Temperature Range
H
2
S:-40 to +122°F (-40 to +50°C)
CO:-22 to +122
°F (-30 to +50°C)
O
2
:-58 to +122°F (-50 to +50°C)
IS approved temperature may not reflect the operating
temperature.
Operating
Temperature Range
H
2
S, CO and O
2
:14 to +122°F (-10 to +50°C)
For values outside this temperature range, you may experience
reduced performance or alarm functionality.
Operating Humidity 5% to 95% RH, Non-Condensing
*Note: These values are factory defaults. These values may be changed.