Specifications
98 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Trouble Zone Type First Area Assignment
When a trouble zone is assigned to an area the zone must be programmed with the type of trouble zone
(Trouble Silent, Trouble Bell etc).
CP001:01 Type 1
Trouble Silent
Use the [1] and [3] keys to scroll the available zone types that can be assigned to the trouble zone. For more
information about the list control data entry refer to the section List Control Data Entry (see page 335).
Trouble Zone Second Area Assignment
The trouble zone must be assigned to an area for it to perform any function in the system. By default ALL
trouble zones are assigned to the predefined trouble area which is the last programmable area in the system. A
trouble zone can be assigned in up to 4 different areas. A trouble zone can perform a different function in each
area.
CP001:01 Area 2
None
Use the [1] and [3] keys to scroll the available areas that can be assigned to the trouble zone. For more
information about the list control data entry refer to the section List Control Data Entry (see page 335).
Trouble Zone Type Second Area Assignment
When a trouble zone is assigned to an area the zone must be programmed with the type of trouble zone
(Trouble Silent, Trouble Bell etc).
CP001:01 Type 2
None
Use the [1] and [3] keys to scroll the available zone types that can be assigned to the trouble zone. For more
information about the list control data entry refer to the section List Control Data Entry (see page 335).
Trouble Zone Third Area Assignment
The trouble zone must be assigned to an area for it to perform any function in the system. By default ALL
trouble zones are assigned to the predefined trouble area which is the last programmable area in the system. A
trouble zone can be assigned in up to 4 different areas. A trouble zone can perform a different function in each
area.
CP001:01 Area 3
None
Use the [1] and [3] keys to scroll the available areas that can be assigned to the trouble zone. For more
information about the list control data entry refer to the section List Control Data Entry (see page 335).
Trouble Zone Type Third Area Assignment
When a trouble zone is assigned to an area the zone must be programmed with the type of trouble zone
(Trouble Silent, Trouble Bell etc).
CP001:01 Type 3
None
Use the [1] and [3] keys to scroll the available zone types that can be assigned to the trouble zone. For more
information about the list control data entry refer to the section List Control Data Entry (see page 335).