Specifications
PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 95
Selecting a Trouble Zone to Modify
Each trouble zone is assigned a unique identification that uses the Protege Notation.
Trouble zone to
modify: CP001:01
Type the appropriate module type, module address and trouble zone number or use the [Ð] and [Ï] keys to
scroll the available trouble zones. When the desired trouble zone number appears on the screen, press [ENTER]
to program the selected trouble zone number.
Trouble Zone Miscellaneous Options
Miscellaneous options for the zone include the configuration of event logging, bypass and arming configurations
for the zone.
CP001:01 Misc
[--------]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).
Option 1 - Log Trouble Zone Event
y Enabled the trouble zone will generate an event whenever it is opened or closed.
The trouble zone will still perform all functions that are programmed if this is not enabled.
y Disabled the trouble zone will not log an event.
Option 2 - Bypassing Not Allowed
y Enabled the trouble zone is a high security trouble zone and cannot be bypassed.
y Disabled the trouble zone can be bypassed.
Option 3 - Bypassing Latched Not Allowed
y Enabled the trouble zone is a high security trouble zone and cannot be latch bypassed (Permanent Bypass).
y Disabled the trouble zone can be latch bypassed.
Option 4 - Trouble Zone State Inverted
y Enabled the trouble zone will operate in an inverted mode.
y Disabled the trouble zone will operate normally.
Option 5, 6, 7 and 8 - Reserved
y Reserved do not modify
Trouble Zone Special Options
Special options for the zone include the configuration of special bypass and wiring settings for the zone.
CP001:01 Special
[--------]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).
Option 1 - No Bypass When Area Armed
y When enabled the zone will be prevented from being bypassed if it is already assigned to an area that has
either the 24HR processing enabled or the area is armed.
y Disabled the zone can be bypassed while it is in an armed condition. This option is not recommended
unless it is required for a specific reason.
Option 2, 3, 4, 5, 6, 7 and 8 - Reserved
y Reserved do not modify