Specifications
PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 93
Zone Fourth Area Assignment
The zone must be assigned to an area for it to perform any function in the system and a zone can be assigned
in up to 4 different areas. A zone can perform a different function in each area. For example a zone can be a
delay zone in one area and an instant zone in another.
CP001:01 Area 4
None
Use the [1] and [3] keys to scroll the available areas that can be assigned to the zone. For more information
about the list control data entry refer to the section List Control Data Entry (see page 335).
Zone Type Fourth Area Assignment
When a zone is assigned to an area the zone must be programmed with the type of zone (Delay, 24HR etc). The
Protege System has twelve predefined zone types as well as user definable zone types.
CP001:01 Type 4
None
Use the [1] and [3] keys to scroll the available zone types that can be assigned to the zone. For more
information about the list control data entry refer to the section List Control Data Entry (see page 335).
Control PGM or PGM Group
You can assign a PGM or PGM group to activate whenever a zone type process's the zone with the activate
zone PGM options enabled. The zone type must have the appropriate zone control PGM options set in the PGM
options. A PGM can be assigned to the zone type and to the zone allowing many to one and one to many
configurations.
CP001:01 Control
pgm: --000:00
To modify the PGM or PGM Group, use the settings as explained in section Entering PGM and PGM Groups
(see page 336).
i
To activate the Control PGM in a zone the zone type used to process the zone must have the zone
control options set. The zone control options are different from the Zone Type control options.
Automation Control Point
An automation control point allows this zone to control an automation point in response to a zone type
configuration. The automation point can be programmed to activate when when the zone opens or closes. An
automation point can be assigned many different functions such as gardening irrigation, lighting circuits, CBus
Circuits and any PGM Output. You must configure the appropriate options to trigger the Automation point in the
Zone Type. An automation point can also be triggered from a zone type allowing many too one and one to
many configurations.
ZT001 Automate
None
Use the [1] and [3] keys to scroll the available automation points and press [ENTER] to select the automation
point displayed. For more information about the list control data entry refer to the section List Control Data Entry
(see page 335).