Specifications

PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 91
Option 4 - Zone Uses 6K8 and 2K2 EOL Resistors
y Enabled the zone will use the 2 EOL resistor wiring configuration with a 6K8 and 2K2 resistor. For this
option to operate you MUST also have option 3 enabled.
y Disabled the zone will use the default EOL resistors if enabled.
Option 5 - Zone Uses 10K and 10K EOL Resistors
y Enabled the zone will use the 2 EOL resistor wiring configuration with a 10K and 10K resistor. For this
option to operate you MUST also have option 3 enabled.
y Disabled the zone will use the default EOL resistors if enabled.
Option 6 - Zone Uses 2K2 and 2K2 EOL Resistors
y Enabled the zone will use the 2 EOL resistor wiring configuration with a 2K2 and 2K2 resistor. For this
option to operate you MUST also have option 3 enabled.
y Disabled the zone will use the default EOL resistors if enabled.
Option 7 - Zone Uses 4K7 and 2K2 EOL Resistors
y Enabled the zone will use the 2 EOL resistor wiring configuration with a 4K7 and 2K2 resistor. For this
option to operate you MUST also have option 3 enabled.
y Disabled the zone will use the default EOL resistors if enabled.
Option 8 - Zone Uses 4K7 and 4K7 EOL Resistors
y Enabled the zone will use the 2 EOL resistor wiring configuration with a 4K7 and 4K7 resistor. For this
option to operate you MUST also have option 3 enabled.
y Disabled the zone will use the default EOL resistors if enabled.
i
When you make a change to the zone options you MUST do a module update for the module the
zone is located on. This INCLUDES the controller. You can do this from the Keypad or from the
Protege System Management Suite.
Zone Reporting Id
The Zone Reporting Id allows the installer to program any reporting number to any zone. This provides an
extremely high level of flexibility to assign true reporting numbers to the zones. A zone that is assigned the same
reporting ID as another zone will result in both the zones reporting that ID.
If a zone is assigned an ID number that is higher than the maximum number that can be reported by a particular
service, the service will use the maximum number that can be assigned for that format.
CP001:01 Report
id: 00000
To enter a value (0-65535), use the keypad as explained in section Entering Decimal Numbers (see page 333)
and press [ENTER]. Setting a reporting ID of 00000 will result in the default reporting id being used for the
service.
Zone First Area Assignment
The zone must be assigned to an area for it to perform any function in the system and a zone can be assigned
in up to 4 different areas. A zone can perform a different function in each area. For example a zone can be a
delay zone in one area and an instant zone in another.
CP001:01 Area 1
None
Use the [1] and [3] keys to scroll the available areas that can be assigned to the zone. For more information
about the list control data entry refer to the section List Control Data Entry (see page 335).