Specifications
PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 81
Option 5 - Swap LED Lock Display
y Enabled the LED display associated with the lock status will follow lock output one. Use this option when a
reader expander is used in an ENTRY and EXIT configuration and only one lock output is controlling the
door.
y Disabled the lock and LED display is processed normally.
Option 6 - Activate Access Level PGM
y Enabled the reader expander will activate the PGM assigned to the users access level that gained access to
the door or reader.
The user must have the allow access level PGM option enabled.
y Disabled the reader will not perform any action on the access level PGM.
Option 7 - Display Card Data
y Enabled the reader expander will display the actual card data received from the reader when the card
number is not known. This can be used to interface with custom third party applications that require their
own processing of card information.
y Disabled the reader will display the card number not found message.
Option 8 - Arm User Area
y Enabled the reader will arm the user's area when they perform a dual presentation of their card to the
associated reader. The users area must still be available in the user area group assigned to the users
access level for this to correctly operate.
y Disabled the reader will not perform any user area arming functions.
Reader Port 2 Extra Options
Options that relate to the extra reader functions.
RD001 R2 Extra
[--------]
To modify options, use the keypad as explained in section
Entering Data Options (see page 336).
Option 1 - Entry Blocked Beam Input
y Enabled the reader expander will process the sense input for beam control. Beam control allows the reader
expander to control a automatic gate that must have it's contacts held open in the even the pathway is
blocked.
y Disabled the reader will not perform beam processing.
Option 2 - Invert Door Contacts
y When the option is enabled the door contact input is inverted. This does not affect the zone input
functionality if it is being used.
y Disabled door contact functions normally.
Option 3 - Invert Bond Sensing Input
y Enabled the reader will invert the bond sensing input.
y Disabled bond sensing will operate normally.
Option 4 - Invert Request to Exit Input
y Enabled the reader will invert the request to exit input.
y Disabled REX input will operate normally.
Option 5 - Invert Request to Enter Input
y Enabled the reader will invert the request to enter input.
y Disabled REN input will operate normally.