Specifications
PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 73
Reader Port 1 Miscellaneous Options
Options that relate to the miscellaneous reader functions.
RD001 R1 Misc
[--------]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).
Option 1 - Disarm Area
y Enabled the reader process will disarm the area designated by the reader type (ENTRY or EXIT) and the
door configuration programmed (If it has an area on the inside or outside assigned).
If this option is enabled and the reader is only used for area control then the area disarmed will be the area
assigned in the area control setting.
y Disabled the reader will not perform any disarm functions.
Option 2 - Allow User Access if Area Armed
y When the option is enabled the user will be granted access based on the access control configuration only
and the area status will not be checked against the user's ability to disarm the area.
y When the option is disabled and the user who is attempting access to a door that has an area assigned that
is armed and the user can not disarm the area the user will be denied entry to the door even though they
may have the correct door and schedule settings.
Option 3 - Disarm User Area
y Enabled the reader will disarm the user's area when access is granted to the door they are attempting to
access. The users area must still be available in the user area group assigned to the users access level.
y Disabled the reader will not perform any user area functions.
Option 4 - Generate Reader Events
y Enabled the reader events will be logged to the event review log.
y Disabled the reader will not log the events to the event review log.
Option 5 - Swap LED Lock Display
y Enabled the LED display associated with the lock status will follow lock output two. Use this option when
a reader expander is used in an ENTRY and EXIT configuration and only one lock output is controlling the
door.
y Disabled the lock and LED display is processed normally.
Option 6 - Activate Access Level PGM
y Enabled the reader expander will activate the PGM assigned to the users access level that gained access to
the door or reader.
The user must have the allow access level PGM option enabled.
y Disabled the reader will not perform any action on the access level PGM.
Option 7 - Display Card Data
y Enabled the reader expander will display the actual card data received from the reader when the card
number is not known. This can be used to interface with custom third party applications that require their
own processing of card information. This option is enabled by default and can be used to add card data to
a user when operating the Protege System Management Suite Application.
y Disabled the reader will display the card number not found message.
Option 8 - Arm User Area
y Enabled the reader will arm the user's area when they perform a dual presentation of their card to the
associated reader. The users area must still be available in the user area group assigned to the users
access level for this to correctly operate.
y Disabled the reader will not perform any user area arming functions.