Specifications

PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 71
i
When a Wiegand 26 Bit or 36 Bit Keypad is used PIN numbers that are prefixed with a 0 can not be
used and a maximum pin number of 65533 can be used for 26 Bit and 999999 for 36 Bit. This is a
limitation of the 26 Bit and 36 Bit Format and not the Reader Expander. To utilize the full 8 digit
capacity for the PIN number of a user and allow prefixed PIN numbers select a PIN device that
supports the ARK-501 or Bit Buffered Outputs.
Reader Port 1 LCD Keypad
If the keypad operation mode is set to use one of the selected LCD keypads you can program the address of
the keypad to use for pin entry. When using this mode of operation the LCD keypad will present a login
message when a valid card is presented that requires pin entry.
RD001 R1 Keypad
None
Use the [1] and [3] keys to scroll the available keypad mode settings. For more information about the list control
data entry refer to the section List Control Data Entry (see page 335).
Reader Port 1 Multi Badge Operation
The reader port can perform various operations when a user badges their card multiple times. The list below
details the modes this can operate in.
When a multi badge operation has taken place the reader expander will beep the buzzer output four times. In
area control, if the area is already armed the reader will only beep twice.
RD001 Arming
Arm on 2 Reads
Use the [1] and [3] keys to scroll the available arming operation settings. For more information about the list
control data entry refer to the section List Control Data Entry (see page 335).
Mode Operation
None No action will be taken by the system for arming an area associated with the door.
Arm on 2 Reads Two successive reads from the same user will result in the inside or outside area
(depending on the card reader type configuration) starting the arming process.
Arm on Card Read
and Zone Input 4
Pressing and holding Zone Input 4 (RDXXX:04) while presenting a card will begin arming.
Zone 4 must be in an area that is armed to ensure the zone information is transmitted to
the system controller. The area armed will depend on the card reader type setting.
This option cannot be used with the PRT-RDM2, Zone 4 is not available on the
module. Use another arming method or use the PRT-RDS2 or PRT-RDI2.
Arm on 3 Reads Three successive reads from the same user will result in the inside or outside area
(depending on the card reader type configuration) starting the arming process.
Toggle Function
PGM
Three successive reads from the same user will result in the function PGM state being
toggled. If the PGM is currently on it will be turned off and if it is off it will be turned on.
Activate Function
PGM
Three successive reads from the same user will result in the function PGM state being
turned on
Reader Port 1 Reader Options
Options that directly relate to the control of reader functions.
RD001 R1 Option
[123-5---]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).