Specifications

64 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Displaying Selected 2 Reader Expander Information
It is possible to show the current 2 Reader Expander registration and information details (registration, online and
version) from the 2 Reader Expander selection display.
2 Reader Exp to
modify: RD001
Type the appropriate 3-digit 2 Reader Expander address or use the [Ð] and [Ï] keys. When the desired
address appears on the screen, press the [ARM] key to display information on the selected 2 Reader Expander.
The screen will now display information about the 2 Reader Expander that was selected. Press any other key to
return to the 2 Reader Expander selection window.
11-14-72-B9 [23]
V 1.31 2404 M RO
The display above represents the following information for the selected keypad:
11-14-72-B9 Serial Number of the registered 2 Reader Expander at the selected address.
[23] The current polling timeout value.
V 1.05 Software version of the registered keypad.
2404 Software version build number.
M This is the module type that is registered at this location.
M - Mini 2 Reader Expander
S - Standard 2 Reader Expander
I - Intelligent 2 Reader Expander
E - Ethernet 2 Reader Expander
R The 2 Reader expander is registered.
('*' will indicate no expander registered)
O The 2 Reader expander is online.
('*' will indicate the expander is offline)
To view the IP address of the module press the [Ï] key from this view. If the module is connected over the
RS-485 LAN "---.---.---.---" will be displayed.
To list all offline or online modules refer to the Module Network Functions (see page 201).
Special functions are provided to update, update reset a module and request offline events from a module. In
the case of a update or update reset this occurs for the individual module however pressing the memory key will
start the event request process for the by using a shortcut key directly from the keypad selection screen.
Key Function
[STAY] Pressing the [STAY] key will update the zone expander number that is currently displayed in
the module selection window. This will program the module WITHOUT resetting the module.
[FORCE] Pressing the [FORCE] key will update and init the zone expander number that is currently
displayed in the module selection window. This will program the module and then restart the
module.
[MEMORY] Pressing the [MEMORY] key will start the system controller in the offline event update mode.
This forces the controller to request all offline events from the Intelligent or Ethernet Reader
Expanders. Pressing the [MEMORY] key while the system controller is already updating the
network or performing other functions the [MEMORY] key will not have any function.