Specifications
PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 59
Option 3 - Event Review Menu
y Enabled the keypad will allow access to the Event Review Menu if no user is logged in and a user press's
the [MENU] key.
y Disabled the keypad will not allow access to the Event Review Menu offline.
Option 4 - Keypad Information Menu
y Enabled the keypad will allow access to the Keypad Information Menu if no user is logged in and a user
press's the [MENU] key. It is recommended to leave this option enabled.
y Disabled the keypad will not allow access to the Keypad Information Menu offline.
Option 5, 6, 7 and 8 - Reserved
y Reserved do not modify
Zone Expander
To access the Zone Expander module programming login using a valid installer code and then select [MENU, 4,
1, 2]. The screen displays "Zone exp to modify" as shown in the following example.
16 Zone Exp to
modify: ZX001
Every time you press the Enter key, the next screen appears. The different screens are described in the
following sub-sections. Programming the Zone Expander allows you to set the polling time of the module and
power supply options.
When programming modules some options are processed at the module, for these options to operate correctly
a network update must be performed and the zone expander must be registered and online.
Updating modules can be accessed by selecting [MENU, 4, 8, 1, 3], you can also check the status of your
modules by selecting [MENU, 4, 8, 1, 1] for all modules presently offline and [MENU, 4, 8, 1, 2] for all online
modules. For more information refer to the Advanced menu section (see page 201).
Selecting a Zone Expander to Modify
Each zone expander is assigned a unique address from 001 to 250. Programming the address of the Zone
Expander Module (PRT-ZX16) is covered in the installation instructions included with your PRT-ZX16 Zone
Expander Module.
16 Zone Exp to
modify: ZX001
Type the appropriate 3-digit Zone Expander address or use the [Ð] and [Ï] keys. When the desired address
appears on the screen, press [ENTER] to program the selected Zone Expander module. The maximum number
of Zone Expanders that can be programmed is limited by your system's memory and configured profile.
Displaying Selected 16 Zone Expander Information
It is possible to show the current 16 Zone Expander registration and information details (registration, online and
version) from the 16 zone expander selection display.
16 Zone Exp to
modify: ZX001
Type the appropriate 3-digit 16 Zone Expander address or use the [Ð] and [Ï] keys. When the desired address
appears on the screen, press the [ARM] key to display information on the selected 16 Zone Expander. The
screen will now display information about the 16 Zone Expander that was selected. Press any other key to
return to the 16 Zone Expander selection window.
92-A8-90-C2 [9F]
V 1.04 1833 RO