Specifications

PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 57
Option 4 - Trouble Display
y Enabled the keypad will lockout any user activity for the programmed lockout time if three invalid PIN
numbers are entered. This option will have no affect if the lockout time is programmed to 0 seconds.
y Disabled the keypad will perform no action on an invalid PIN.
Option 5 - Bypassed Zone Display
y When enabled the keypad will display the message zone(s) bypassed when a zone has been bypassed in
the system or primary area depending on the setting of option 7. Bypassed zones can be viewed by going
to the bypass view menu [MENU, 5, 2]. This option can be programmed to only show the primary area
bypassed zones by setting option 7.
y Disabled the keypad will not show the bypassed zones message.
Option 6 - Alarm Memory Display
y When enabled the keypad will display the message alarm(s) in memory. Alarms can be viewed by going to
the alarm view menu [MENU, 5, 1]. This option can be programmed to only show the primary area alarms
by setting option 7.
y Disabled the keypad will show not show the alarm memory status.
Option 7 - Display Only Primary Area
y When enabled with option 6 being enabled the keypad will only display the bypassed zone status and alarm
memory for the primary area of the keypad.
Setting this option with option 7 means that ONLY the primary area's alarms is shown. In which case, the
alarm message is cleared ONLY if the primary area's memory is acknowledged.
If option 7 is not turned on then ANY area that has an alarm stored in memory is shown and ALL the areas'
memory must be acknowledged before this message is cleared.
y Disabled the keypad will display the alarm memory and bypassed zones in the system.
Option 8 - Display Area Defer Arming Warnings
y When enabled the keypad will allow defer messages to be shown on the keypad for any area that is in the
defer mode and the keypad is part of the defer warning keypad group.
y Disabled the keypad will not display any defer messages regardless of the defer area keypad group.
Keypad Access Options
Options that relate to the keypad access control functions and some specific area control menu settings.
KP001 Access
[--------]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).
Option 1 - Unlock Controlled Door
y Enabled the keypad will allow a user to unlock the controlled door by pressing the [FUNCTION] key.
y Disabled the keypad performs no action when the function key is pressed and held. The function key may
still be used for home automation or control functions if enabled for the keypad.
Option 2 - Strict Primary Area Status Display
y Enabled the keypad will only display the primary area and will not show ANY other areas regardless of the
programmed options for the logged in user or the keypad security settings.
y Disabled the keypad will function normally using the area configuration and user area settings.
Option 3 - 24 Hour Area Access
y Enabled the keypad will allow the 24Hr status screen of an area to be accessed by pressing the [Í] key
when the user is logged in and at the area display screen. The user must have the 24Hr menu option set.
y Disabled the keypad will not display the 24 Hour area status screen.