Specifications

56 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Keypad Module Options
Options that relate to the keypad module can be set using option entry.
KP001 Module
[1-34----]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).
Option 1 - Beep on Key Press
y Enabled the keypad will NOT beep when a key is pressed.
y Disabled the keypad will generate a beep tone each time a key is pressed.
Option 2 - Zone Duplex Operation
y Enabled the keypad will enable the
Duplex Zone
option making it possible to connect four zone inputs to
the keypad.
y Disabled the keypad will use the standard zone configuration settings.
Option 3 - Keypad Lockout
y Enabled the keypad will lockout any user activity for the programmed lockout time if three invalid PIN
numbers are entered. This option will have no affect if the lockout time is programmed to 0 seconds.
y Disabled the keypad will perform no action on an invalid PIN.
Option 4 - Keypad Lockout
y Enabled the keypad will allow the [CLEAR] / [X] key to disable the beeper on the keypad. You must hold the
key for two seconds.
y Disabled the [CLEAR] / [X] will not perform any action.
Option 5, 6, 7 and 8 - Reserved
y Reserved do not modify
Keypad Display Options
The following options determine which screens will be displayed when the keypad is offline. The keypad is offline
when no valid user code (PIN) has been entered. By default the keypad will display the system message
programmed in to the panel configuration settings.
KP001 Display
[1-------]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).
If all message options are disabled the LCD Keypad will display a standard system is ready message on the
display.
Option 1 - System Message Display
y Enabled the keypad will display the text programmed in the panel system message setting.
y Disabled the keypad will not display the system text message.
Option 2 - Primary Area Status Display
y Enabled the keypad will display the status of the primary that is assigned to the keypad.
y Disabled the keypad will not display the primary area status.
Option 3 - Area Group Status Display
y Enabled the keypad will display the status of the area's that are assigned in the area group. Each area is
presented on screen and can be scrolled using the [Ð] and [Ï] keys.