Specifications

PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 55
Keypad Control Door
The keypad control door configured will be is used by the keypad when the door control option is enabled. This
allows a door to be unlocked (similar to a request to exit) by pressing and holding the [FUNCTION] key for two
seconds.
KP001 Ctrl Door
None
Use the [1] and [3] keys to scroll the door selection. For more information about the list control data entry refer
to the section List Control Data Entry (see page 335).
Keypad Auto Logout Time
When the user does not perform any action on the keypad for the time programmed in the logout time the
keypad will automatically log the user out. Programming the option Never Logout should be avoided unless for
training or demonstration purposes.
KP001 Logout
10 Sec
Use the [1] and [3] keys to scroll the auto logout time selection. For more information about the list control data
entry refer to the section List Control Data Entry (see page 335).
Keypad Dual User Entry Time
When the keypad is set to require dual-code entry, the dual-code entry time determines how long the users
have to enter both codes. Dual code entry is primarily used for the control of ATM and Banking applications. For
example, if the time is set to 025 seconds, the dual-code master and dual code provider must successfully
enter their codes within 25 seconds in order to gain access. The dual-code can be overridden only by a user
that has the dual-code override option set (Super User Option).
KP001 Dual
time: 020 secs
To enter a dual user entry time (001 to 250 seconds), use the keypad as explained in section Entering Decimal
Numbers (see page 333) and press [ENTER].
Keypad Invalid Code Lockout Time
If the Lockout option is enabled for the selected keypad and the maximum number of incorrect user codes (PIN
Numbers) is reached (3 Times), the time programmed here defines how long the keypad will be locked out.
During this period, the keypad will display the lockout message and ignore all key entries or login attempts by ay
user. A lockout time of 0 seconds will disable this function regardless of the lockout option setting.
KP001 Invalid
time: 060 secs
To enter a lockout time (001 to 250 seconds), use the keypad as explained in section Entering Decimal
Numbers (see page 333).
Keypad Smoke Detector Reset PGM
The PGM that is programmed as the keypad smoke detector reset PGM will be activated when a user press's
the [CLEAR + ENTER] keys together. The selected PGM should have a time programmed of 5 to 10 seconds,
for information on setting a PGM activation time refer to the PGM Programming section (see page 108).
KP001 Smoke
pgm: -----:--
To enter a smoke detector PGM, use the keypad as explained in section Entering PGM and PGM Groups (see
page 336).