Module Polling Time
The polling time defines how often the LCD Keypad checks in with the Protege System Controller. If a LCD
Keypad fails to check in, it triggers its associated communications failure trouble zone (KPxxx:08) and the
trouble zone for a general module communications failure.
To enter a polling time (008 to 250 seconds), use the keypad as explained in section Entering Decimal Numbers
(see page 333) and press [ENTER]. By default the LCD Keypad polling time is set to 250 seconds. Setting a
polling time below 60 seconds should only be done for keypads that are in a non-secure area.
KP001 Polling
time: 250 secs
i
For UL and ULC listed installations you MUST set the polling time to 180 seconds or less.
Keypad Primary Area
The primary area for the keypad is the area that the keypad will display first on all area display modes. The
primary area should belong to the keypad's area group, if any area actions are to be performed on the keypad.
For more information on area security refer to the Area Security section (see page 16).
KP001 Primary
*Area 001
Use the [1] and [3] keys to scroll the primary area selection. For more information about the list control data
entry refer to the section List Control Data Entry (see page 335).
Keypad Menu Group
Users can only access a menu assigned to the keypad if the same menu is also assigned to the user. This is
also applicable if a menu is assigned to a user, but not to the keypad, the user cannot have access to the menu
on the keypad. If you select "None", the user has access to all menus defined by the user's menu group.
KP001 Menu Grp
None
Use the [1] and [3] keys to scroll the menu group selection. For more information about the list control data entry
refer to the section List Control Data Entry (see page 335).
Keypad Area Group
Users can only access an area assigned to the keypad if the same area is also assigned to the user's arm
and/or disarm area group. For more information on which areas are displayed by the keypad refer to the Area
Security section (see page 16).
KP001 Area Grp
None
Use the [1] and [3] keys to scroll the area group selection. For more information about the list control data entry