Specifications
42 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Elevator Floor Group
An elevator floor group is assigned to an access level to allow a user to access floors within the elevator cars
that are assigned.
AL001 Floor Grp
All Floors
Use the [1] and [3] keys to scroll the elevator floor group selection and press [ENTER] to select the elevator floor
group displayed. For more information about the list control data entry refer to the section List Control Data
Entry (see page 335). For information on Floor Group programming refer to the section Floor Groups (see page
46).
Access Level Miscellaneous Options
These options relate to miscellaneous operation of the access level. These include the operation of PGM
activation functions.
AL001 Misc
[--------]
To modify options use the relevant key from 1 to 8 to toggle the state of the option.
Option 1 - Activate Access Level PGM on Keypad Access
y Enabled the access level's PGM activates when a user with this access level assigned enters a valid user
code on a LCD Keypad.
For this option to work, the Activate Access Level PGM option must be turned on for the keypad that is
being logged into by the user.
y Disabled the access level PGM will perform no function.
Option 2 - Activate Access Level PGM on Card Access
y Enabled the access level's PGM activates when a user with this access level assigned presents a valid card
to a card reader.
For this option to work, the Activate Access Level PGM option must be turned on for the card reader that is
being used.
y Disabled the access level PGM will perform no function.
Option 3 - Validate Access Level If Qualify PGM is on
y Enabled the access level will only be valid if the qualify PGM programmed in the qualify PGM entry screen is
turned on.
For this option to work, the Qualify PGM must be programmed with a valid PGM number. If option 3 and 4
are enabled only option 3 will be used.
y Disabled the qualify PGM will not be checked.
Option 4 – Validate Access Level If Qualify PGM is off
y Enabled the access level will only be valid if the qualify PGM programmed in the qualify PGM entry screen is
turned off.
For this option to work, the Qualify PGM must be programmed with a valid PGM number. If option 3 and 4
are enabled only option 3 will be used.
y Disabled the qualify PGM will not be checked.
Option 5, 6, 7 and 8 - Reserved
y Reserved do not modify