Specifications

PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 37
Selecting a Door Group to Modify
Each door group is assigned a unique door group number from 001 to 250.
Door Group to
modify: DG001
Type the appropriate 3-digit door group number or use the [Ð] and [Ï] keys to scroll the available door groups.
When the desired door group appears on the screen, press [ENTER] to program the selected door group. The
maximum number of door groups that can be programmed is limited by your system's memory and configured
profile.
Door Group Name
If the selected door group has a name associated (some door groups do not have a name associated with
them) the name programming screen will be shown.
DG001 Name
All Doors
To scroll door groups by name use the [Ð] and [Ï] keys. To modify or enter a new name for the selected door
group use the keypad as explained in section Entering Text and Names (see page 333) and press [ENTER].
By default the door group name will be prefixed by an '*' this indicates that the name is an editable name in the
system.
Operating Schedule
The operating schedule for the door group determines when the door group is valid and if it will use a secondary
door group if the schedule is not valid. A schedule is a series of times and days that can be programmed to
prevent the operating of functions based on a 7 day week and 24 hour clock. For more information on the
programming of the schedule refer to the Schedule Programming section (see page 272).
DG001 Schedule
None
Use the [1] and [3] keys to scroll the schedule selection and press [ENTER] to select the schedule displayed.
For more information about the list control data entry refer to the section List Control Data Entry (see page 335).
Secondary Door Group
A secondary door group can be selected that will be used when the schedule of the door group that is
programmed is not valid. The schedule of the secondary door group must be valid or set to none. The
secondary door group allows very powerful door group controls to be placed on users during certain times of
the day preventing access to certain doors.
DG001 Secondary
None
Use the [1] and [3] keys to scroll the secondary door group selection and press [ENTER] to select the door
group displayed. For more information about the list control data entry refer to the section List Control Data
Entry (see page 335). Programming a secondary door group that uses the current area group being edited will
perform no function.